查看: 9682|回复: 7

交换机端口不停DOWN UP,请各位分析一下

[复制链接]
发表于 2010-12-15 09:24:02 | 显示全部楼层 |阅读模式
研发部交换机是普通交换机,公司核心交换机是H3C S3100,现在是研发部交打换机每天早上通电后,和核心交换机相连的那个接口就会不停DOWN UP,DOWN UP个十来分钟后就可以正常上网了,然后一天相安无事,就是中途断电,在接上也不会出现DOWN UP现象!到明天又开始这种现象了!
这是交换机上的日志
Apr  4 17:32:02:162 2000 H3C L2INF/5/PORT LINK STATUS CHANGE:- 1 -
Ethernet1/0/16: is UP
%Apr  4 17:32:02:782 2000 H3C L2INF/5/PORT LINK STATUS CHANGE:- 1 -
Ethernet1/0/16: is DOWN
%Apr  4 17:32:04:662 2000 H3C L2INF/5/PORT LINK STATUS CHANGE:- 1 -
Ethernet1/0/16: is UP
%Apr  4 17:32:05:283 2000 H3C L2INF/5/PORT LINK STATUS CHANGE:- 1 -
Ethernet1/0/16: is DOWN
%Apr  4 17:32:34:628 2000 H3C L2INF/5/PORT LINK STATUS CHANGE:- 1 -
Ethernet1/0/16: is UP
%Apr  4 17:32:35:251 2000 H3C L2INF/5/PORT LINK STATUS CHANGE:- 1 -
Ethernet1/0/16: is DOWN
%Apr  4 17:32:37:128 2000 H3C L2INF/5/PORT LINK STATUS CHANGE:- 1 -
Ethernet1/0/16: is UP

下面这个是用科来抓的五分钟包

本帖子中包含更多资源

您需要 登录 才可以下载或查看,没有账号?CSNA会员注册

×
回复

使用道具 举报

发表于 2010-12-15 09:51:09 | 显示全部楼层
你查看一下err-disable  然后配置 errdisable recovery  
注:cisco 是这样 你可以参考一下华为的具体配置
回复

使用道具 举报

发表于 2010-12-15 10:05:12 | 显示全部楼层
查看一下在交换机端口上有没有开启一些保护机制能?
回复

使用道具 举报

 楼主| 发表于 2010-12-15 11:06:51 | 显示全部楼层
[H3C]dis int e1/0/16
Ethernet1/0/16 current state : UP
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 000f-e254-70b2
Media type is twisted pair, loopback not set
Port hardware type is 100_BASE_TX
100Mbps-speed mode, full-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
Flow-control is not enabled
The Maximum Frame Length is 9216
Broadcast MAX-ratio: 100%
Unicast MAX-ratio: 100%
Multicast MAX-ratio: 100%
Allow jumbo frame to pass
PVID: 1
Mdi type: auto
Port link-type: access
  Tagged   VLAN ID : none
  Untagged VLAN ID : 1
Last 300 seconds input:  75 packets/sec 10902 bytes/sec
Last 300 seconds output:  95 packets/sec 81763 bytes/sec
Input(total):  6168871 packets, 1273367351 bytes
         114310 broadcasts, 3581 multicasts, 0 pauses
Input(normal):  - packets, - bytes
         - broadcasts, - multicasts, - pauses
Input:  32 input errors, 0 runts, 0 giants,  - throttles, 1 CRC
         0 frame,  - overruns, 31 aborts, 0 ignored, - parity errors
Output(total): 7527422 packets, 5990287529 bytes
         129982 broadcasts, 23462 multicasts, 0 pauses
Output(normal): - packets, - bytes
         - broadcasts, - multicasts, - pauses
Output: 0 output errors,  - underruns, - buffer failures
         0 aborts, 0 deferred, 0 collisions, 0 late collisions
         0 lost carrier, - no carrier


这是正常上网时候的SHOW!
回复

使用道具 举报

发表于 2010-12-15 12:33:43 | 显示全部楼层
可以把这个:
100Mbps-speed mode, full-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
看下对端接口,调整为强制百兆全双工。
另外可以换一个接口试一下.
回复

使用道具 举报

发表于 2010-12-15 12:54:32 | 显示全部楼层
同意楼上,有可能速率不匹配。
回复

使用道具 举报

您需要登录后才可以回帖 登录 | CSNA会员注册

本版积分规则